41
Group Name Cmd
RespDescription
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
PE_SIZE_H pW pW
Layer H size on output screen
(without borders)
Rd/Wr 0 65535
1600
Unit = pixels ( Max=16x2048 =
32768)
0 = Current preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset
1
4 = Memory Preset
2
5 = Memory Preset
3
6 = Memory Preset
4
7 = Memory Preset
5
8 = Memory Preset
6
9 = Memory Preset
7
10 = Memory
Preset 8
0 = Background
Frame for output 1
1 = Background
Frame for output 2
in matrix mode
2 = Background
Layer for output 1
3 = Pip 1 Layer for
output1
Background Layer
for output 2 in
matrix mode
4 = Pip 2 Layer for
output1
5 = Pip 3 Layer for
output1 in
quadravision mode
Pip1 Layer for
output 2 in matrix
mode
6 = Logo 1
7 = Logo 2
8 = Audio Output 1
9 = Audio Output 2