Group Name CmdResp
Description
Read
/
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
SET_BRIGHTNESS Sg Sg Input brightness
Rd/Wr
0 255 128 128 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_CONTRAST Sc Sc Input Contrast
Rd/Wr
0 255 128 128 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_COLOR Sr Sr Input color level
Rd/Wr
0 255 128 128 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_HUE Su Su Input hue (NTSC only)
Rd/Wr
0 255 128 128 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
8 = Input9
9 = Input10
10 = Input11
11 = Input12