Group Name Cmd
Resp
Description
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
SIG_FORMAT_LIST sL sL
Bit field of the fomats compatible
with the detected format
Rd 0 255 0
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
0 = Bits 0 to 7
Slice
1 = Bits 8 to 15
Slice
2 = Bits 16 to 23
Slice
3 = Bits 24 to 31
Slice
4 = Bits 32 to 39
Slice
5 = Bits 40 to 47
Slice
SIG_SCANTYPE ss ss Input scan type Rd 0 3 0
0 = Progressive
1 = Interleaved, Top field first
2 = Interleaved, Bottom field first
3 = Segmented frame
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
SIG_HTOTAL_THEORIC sH sH Total number of pixels per line Rd 0 65535
0 Unit = pixels
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
SIG_HTOTAL_MAXI sM sM
Maximal number of pixels per
input line
Rd 0 65535
0 Unit = pixels
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
SIG_WIDTH sw sw Input displayed pixel count Rd 0 65535
0 Unit = pixels
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
SIG_HEIGHT st st Input displayed line count Rd 0 65535
0 Unit = pixels
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
SIG_HDCP sn sn Input HDCP status Rd 0 1 0
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9