Analog-way ASCENDER 16 (LIVECORE) - Ref. ASC1602 User Manual Uživatelský manuál Strana 105

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 118
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 104
105
10.1 Addive Modularity Linked mode
10. ASSEMBLING AND DEVICES COUPLING
The LiveCore™ unit can be used in mulple device conguraon to share informaon between device chassis.
This can enable large setups such as a large mul-device screen blend (Hard Edge and So Edge).
LiveCore™ units can be linked in two modes:
 allows two units (except NeXtage 16) to share the combined resources
of up to all 24 inputs, 8 outputs, and 2 operators monitors using a set of three Livecore Link cables plus a
LAN cable for synchronizaon. Any input can be routed to any layer on any output, and any combinaon of
screens can be used, up to 8 outputs blended.
Analog Way cable
 allows for up to four units to be used as part of the same Assembly on the
Verge™ console. The Device Sync connecon assists with synchronizaon between the various units. In
Associave Modularity conguraon, video informaon must be externally split and shared with all devices
in the Assembly.

Once the two devices are wired up, ensure that all devices have unique IP addresses on the network, and
that the gateway IP of all devices is set correctly. If you are not using a router on the network, set all of
the gateway IP addresses to the rst or last IP on the network, for example 192.168.2.1 and do not use this
address for any other device.
Lastly, connect to one of the two units, go to the SETUP >PRECONFIG >LINKED PAGE, select Linked mode,
and click Refresh to check the connecons. If all 5 connecon parameters are green, click Start and the units
will synchronize and self-congure for linked operaon. If any conguraon parameter is red, x the error
and click Refresh again. All units must be running the same rmware or you will not be able to iniate the
Link mode.
DEVICE MASTER DEVICE SLAVE
RJ-45
OPT-LINK (x3)
LINK 1
LINK 2
LINK 3
RJ-45
RJ-45
OUT IN
Web RCS
(Remote Control Soware)
On Device Master
ETHERNET HUB
Zobrazit stránku 104